Products · Firefighting pumps
UL/FM Approved Fire Pump Sets
Internationally approved fire pump sets with electric, diesel and jockey pumps, supplied from top global manufacturers, installed to NFPA standards, then tested and commissioned by our team.

- Drivers
- Electric · Diesel · Jockey
- Approvals
- UL Listed · FM Approved
- Installation standard
- NFPA 20
- Our scope
- Supply to commissioning

The package
What a fire pump set includes
Each set is configured to the project’s rated flow and pressure. A typical package brings together:
- Main fire pump: horizontal split case, end suction or vertical
- Electric motor or diesel engine driver
- Listed fire pump controller for the driver
- Jockey pump and controller to hold system pressure
- Common base frame, couplings and guards
- Suction and discharge valves, gauges and relief valve
- Test header or flow meter for performance testing
Driver options
Electric, diesel and jockey pumps
Most systems combine a main pump, a standby driver and a jockey pump. Choose a driver to compare.

01 / 03
Electric motor-driven fire pump
The main duty pump on most systems where a reliable power supply is available. Started automatically by its listed controller when system pressure drops.
- Listed electric fire pump controller
- Automatic start on pressure drop
- Simple, low-maintenance driver
Pump types
The right pump for the duty
Horizontal split case
High flows and long service life; the casing opens for maintenance without disturbing pipework.

End suction
A compact, economical choice for small and medium flows.
Not sure which configuration you need?
Send us your design documents or duty point, and we will select and size the set with you.
Ask our team
NFPA 20 performance
Performance you can verify
Listed fire pumps are tested to the NFPA 20 performance envelope. At commissioning we run the set against its curve and record the results.
- 1ChurnAt zero flow, pressure must not exceed 140% of rated pressure
- 2Rated point100% of rated flow at 100% of rated pressure
- 3OverloadAt 150% of rated flow, at least 65% of rated pressure
Standards & approvals
Listed, approved and installed to code
The standards behind a UL/FM fire pump set, from the pump to its controller and installation.
NFPA 20
Installation of stationary pumps for fire protection
UL 448
Centrifugal stationary pumps for fire-protection service
FM Class 1311
Approval standard for centrifugal fire pumps
UL 218 · FM 1321/1323
Fire pump controllers, electric and diesel
Reference projects
Fire pump sets we have delivered

1000 GPM @ 8 barUL/FM fire pump set
Al Mana General Hospital
Jeddah
Supply, installation and commissioning of one UL/FM approved SPP fire pump set, 1000 GPM @ 8 bar.

500 GPM @ 115 psiUL/FM fire pump set
SINOHYDRO – Riyas Project
Jubail
Supply, testing and commissioning of a UL/FM approved fire pump set, 500 GPM @ 115 psi (Fairbanks).
FAQ
Common questions
What is the difference between UL/FM and non-UL/FM fire pump sets?
UL/FM sets use pumps, drivers and controllers that are UL Listed and FM Approved, as many projects, insurers and authorities require. Where a listed set is not required, we also offer locally assembled non-UL/FM fire pump sets with electric, diesel and jockey pumps.
Do I need an electric pump, a diesel pump, or both?
It depends on the reliability of the power supply and the project’s fire protection design. Many systems pair an electric main pump with a diesel standby pump, plus a jockey pump. We can review your design documents and advise.
What does a jockey pump do?
It keeps the fire protection network at standby pressure by making up small losses, so the main fire pump starts only when a sprinkler, hydrant or test valve actually opens.
Do you install and commission the set?
Yes. We install fire pumps following NFPA standards, then test and commission the set to confirm it meets the manufacturer’s recommendations and the design requirements, keeping it eligible for warranty service.
Related products & services
From supply to upkeep
- 01Non-UL/FM Fire Pump SetsFirefighting pumps
- 02Control & Distribution PanelsPanels
- 03Testing & CommissioningVerified installation that keeps supplied equipment eligible for warranty.
- 04Installation ServicePump installation to manufacturer standards and NFPA standards for fire pumps.
- 05Inspection ServicePeriodic inspection and testing that protect you from costly pump failures.
- 06Maintenance ServiceEfficient, reliable pumping-station maintenance across Saudi Arabia for industrial, commercial and utility operations.
Request a quote
Complete water & electricity systems, from one partner.
Tell us about your project: pumps, fire pump sets, control or distribution panels, or service work. Our team will get back to you with a quotation.